人民长江
• 论文 • 上一篇 下一篇
韩四满 李秀广 王博 郭飞 相中华 谢海滨
出版日期:
发布日期:
Online:
Published:
摘要: 介绍了一起±660kV换流变压器故障诊断分析情况。通过油色谱在线装置,发现了该换流变压器油中的溶解气体异常,然后通过调整负荷对该变压器故障进行了定性。在停电检查的过程中,根据该换流变压器的结构特点,在各柱的不同分接位置开展了温升试验,同时还提取油样开展了油色谱分析,并对试验结果进行了综合分析。根据分析结果,初步确定了故障部位以及故障原因,最后通过解体检查,验证了试验的有效性和准确性。可为今后开展此类变压器故障诊断及定位提供借鉴与参考。
关键词: 换流变压器,  , 油色谱分析,  , 故障分析
Abstract:
The diagnosis and analysis of a ±660kV converter transformer fault is introduced. The dissolved gas in the oil of the converter transformer was found abnormal through the oil chromatogram on-line device, and the nature of the transformer fault was determined by adjusting the load. In the blackout check process, according to the structural characteristics of the converter transformer, a temperature rise test was carried out according to different connective positions of columns; the oil chromatogram analysis was conducted by oil samples. The location and causes of the fault were initially determined. The validity and accuracy of the test was verified by disassembly inspection, which can provide reference for diagnosis and locating of similar transformer faults.
Key words: converter transformer, oil chromatogram analysis, fault analysis
韩四满 李秀广 王博 郭飞 相中华 谢海滨. 某±660kV换流变压器故障分析[J]. 人民长江, doi: 10.16232/j.cnki.1001-4179.2016.19.021.