人民长江

• 论文 • 上一篇    下一篇

基于动态高密度视电阻率法的防渗墙底界判定

雷卫佳,涂序龙,胡雄武,周官群,吴小平,陈兴海,董亚   

  • 出版日期:2020-08-28 发布日期:2020-08-28

Bottom boundry detecting of cut-off wall based on dynamic high density apparent resistivity method

LEI Weijia, TU Xulong, HU Xiongwu, ZHOU Guanqun, WU Xiaoping, CHEN Xinghai, DONG Ya   

  • Online:2020-08-28 Published:2020-08-28

摘要: 防渗墙广泛应用于堤坝防渗处理,为确保其抗渗能力,需对墙体底界进行检测。为提高对防渗墙底界的判定能力,提出了动态高密度视电阻率测试方法。构建了防渗墙物理模型,并在模型两侧分别布置了高密度电法测试系统和钻孔,通过测试钻孔注入盐水前后的动态电性参数,发现视电阻率及其变化率对受注水影响的地质体敏感,初步确定注水后的地质体视电阻率变化率约为15%时可作为模型底界判定的依据。工程实践进一步证实了研究方法的有效性和可靠性。

关键词: 防渗墙底界, 高密度电法, 视电阻率, 防渗墙无损检测,

Abstract: Cut-off wall is widely used in anti-seepage treatment of embankment. In order to ensure its impermeability, it is necessary to detect the bottom boundary of the wall. In this paper, a dynamic high density apparent resistivity test method was proposed to improve the detecting ability of bottom boundary. Firstly a physical model of cut-off wall was constructed, and then the high density electric test system and borehole were arranged on two sides of the wall. The dynamic electrical parameters before and after borehole injection of brine were tested. It was found that the apparent resistivity and its change rate were sensitive to the geological bodies affected by water injection. When the change rate of apparent resistance of geological bodies after water injection was about 15%, it could be used as the basis for determining the bottom boundary of the wall. Engineering practice further showed the effectiveness and reliability of the research method.

Key words: bottom boundary of cut-off wall, high-density electrical method, apparent resistivity, change rate of apparent resistivity,